Duram COGO Personal Escape Mask

169.26

115.00 Incl. Tax 142.60

Product code: DRM002

Duram COGO mask

  • Description
  • HUOM. POISTUVA TUOTE - VARASTOSSAMME 1 KPL

    Simple solution, powerful protection

    Duram masks combine small size and weight for easy access, functional design for easy use with a high efficiency multi-layer filter, elastic hood and large visor for maximum protection in an instant.

    COGO Smoke Escape Mask (EN 403)

    A personal respiratory protective device intended for self-rescue during emergency situations where smoke and hazardous fumes are present. The COGO
    provides users with short-term respiratory protection against smoke and Carbon Monoxide (CO) inhalation and filters the following gases: HCl, HCN and Propenal.
    The COGO mask complies with European Standard EN-403 and CE mark. The COGO has been custom crafted to meet the needs of the following industries:

    * Chemical and petrochemical
    * Emergency services / first responders
    * Law enforcement agencies
    * High-rise office/residential developments
    * Hospitals
    * Hotels

    Technical Data:

    Hood: 

    Special Polychloroprene Latex compound
    Elongation at break: >700%
    Tensile strength: >150 kg / cm ²
    Temperature resistant: 200 ° C
    Fire-resistant to the requirements of NFPA 701.

    Visor:

    ETFE film – a copolymer of Polytetrafluorethylene+ Ethylene monomer.
    Tensile strength: 50N/mm ²
    Elongation at break: 450%
    Tear resistance: 500 N / mm
    Temperature resistance: 150 ° C
    Flame retardant: UL 94 V-O
    Light transmission: >95%

    Filter Assembly:

    Two canisters containing
    * Electrostatic particle filter
    * Layers of impregnated activated charcoal cloth
    * Catalyst
    * Desiccant

    Breathing Device

    A device combining two valves for exhalation and inhalation+ a soft mouthpiece, all in one unit.


    Approximate (package) dimensions: 10x12x14 cm
    Approximate (package) weight: 650 gr

    Performance test data

    Test Gas Gas
    Concentration
    (ml/m3)
    Flow Rate
    (l/min)
    Breakthrough
    Criteria
    (EN 403)
    Breakthrough
    Time
    Propenal (Acrolein) 100 30 >15 min (at 0.5 ml/m3)  20 min
    Hydrogen Chloride (HCl) 1000 30  >15 min (at 5 ml/m3)    > 15 min
    Hydrogen Cyanide (HCN) 400 30  >15 min (at 10 ml/m3)    > 15 min
    Carbon Monoxide (CO) 10,000 30

    Total amount of CO
    penetrated during
    15 min < 200 ml

     33 ml
    during 15 min

     

    Test Requirement (EN 403) Test Results
     Particle filter penetration  < 6 %    < 1.3 %
    Inhalation resistance   < 8 mbar   3.6 mbar
     Exhalation resistance  < 3 mbar  1.1 mbar
     CO2 content of inhalation air    < 2.0 %  < 1.9 %
     Protection Factor   > 50   > 50